Milwaukee EC60 PRO Waterproof 3-in-1 EC / TDS/Temp Tester with Replaceable Probe

Description

The Milwaukee EC60 PRO Conductivity Tester is designed for hydroponic and other growers to help you make sure that your plants have the ideal amount of nutrient avaiable. Keep EC in your target range to help your achieve better results.
DESIGN FEATURES
Measures conductivity and TDS with automatic temperature compensation.
Ideal range for hydroponic and other growers (0.00 to 20.00 mS/cm).
Units in mS/cm or ppt easily convertable to ppm.
Factory calibrated with the ability to recalibrate if needed.
Replaceable electrode.
Fully waterproof to IP65.
Approximately 100 hours of use (4 x 1.5V batteries included).
CARE AND USE
MAINTENANCE
EC electrodes can develop nutrient build up over time. To miminize build up, always rinse the probe in fresh tap water after every use.
CONVERTING EC TO TDS
The Milwaukee EC60 PRO Conductivity Tester, like all conductivity meters, provides a measure of electrically charged ions in a solution and is an absolute measure of conductivity.In Hydroponics, EC is often converted to TDS in parts per million (ppm). Different scales include the 500 scale, 650 scale and the 700 scale. However, true PPM can only be determined through chemical analysis.Your mS/cm reading can be approximately converted to TDS (ppm) as shown in the examples below.2.00 mS/cm = 2000 uS/cm = 1000 ppm on .50 factor scale2.00 mS/cm = 2000 uS/cm = 1400 ppm on the 442 scale or .70 factor scale
SPECIFICATIONS
EC Range: 0.00-20.00 mS/cm
TDS Range: 0.00-10.00 ppt
Temp Range: 0.0 to 60.0°C / 32.0 to 140.0°F
EC Resolution: 0.01 mS/cm
TDS Resolution: 0.01 ppt
Temp Resolution: 0.1°C / 0.1°F
EC Accuracy: 2% Full Scale
TDS Accuracy: 2% Full Scale
Temp Accuracy: ±0.5°C / ±1°F
EC Typical EMC Deviation: 2% Full Scale
TDS Typical EMC Deviation: 2% Full Scale Temp
Typical EMC Deviation Temperature: ±0.5°C / ±1°F
Calibration: Automatic, 1 point
Temperature Compensation: Automatic, with β=0.0 to 2.4%/°C
Probe: Mi59P (replaceable)
Environment: 0 to 50°C / 32 to 122°F; max RH 100%
Battery Type: 4 x 1.5V; IEC LR44, A76 (included)
Battery Life: Approx. 100 hours of use
Auto-off: After 8 minutes of non-use
Dimensions: 7.9 √ó dia 1.5 inches
Weight: 3.5 ounces

Milwaukee EC60 PRO Waterproof 3-in-1 EC / TDS/Temp Tester with Replaceable Probe

Product form

The Milwaukee EC60 PRO Conductivity Tester is designed for hydroponic and other growers to help you make sure that your... Read more

Out of stock, 1-3 weeks

$60.00

    • Guaranteed secure & safe checkout.

      shop pay
    • Free pickup at our Webster & Milford stores
    • 30-day returns on unopened items

    Description

    The Milwaukee EC60 PRO Conductivity Tester is designed for hydroponic and other growers to help you make sure that your plants have the ideal amount of nutrient avaiable. Keep EC in your target range to help your achieve better results.
    DESIGN FEATURES
    Measures conductivity and TDS with automatic temperature compensation.
    Ideal range for hydroponic and other growers (0.00 to 20.00 mS/cm).
    Units in mS/cm or ppt easily convertable to ppm.
    Factory calibrated with the ability to recalibrate if needed.
    Replaceable electrode.
    Fully waterproof to IP65.
    Approximately 100 hours of use (4 x 1.5V batteries included).
    CARE AND USE
    MAINTENANCE
    EC electrodes can develop nutrient build up over time. To miminize build up, always rinse the probe in fresh tap water after every use.
    CONVERTING EC TO TDS
    The Milwaukee EC60 PRO Conductivity Tester, like all conductivity meters, provides a measure of electrically charged ions in a solution and is an absolute measure of conductivity.In Hydroponics, EC is often converted to TDS in parts per million (ppm). Different scales include the 500 scale, 650 scale and the 700 scale. However, true PPM can only be determined through chemical analysis.Your mS/cm reading can be approximately converted to TDS (ppm) as shown in the examples below.2.00 mS/cm = 2000 uS/cm = 1000 ppm on .50 factor scale2.00 mS/cm = 2000 uS/cm = 1400 ppm on the 442 scale or .70 factor scale
    SPECIFICATIONS
    EC Range: 0.00-20.00 mS/cm
    TDS Range: 0.00-10.00 ppt
    Temp Range: 0.0 to 60.0°C / 32.0 to 140.0°F
    EC Resolution: 0.01 mS/cm
    TDS Resolution: 0.01 ppt
    Temp Resolution: 0.1°C / 0.1°F
    EC Accuracy: 2% Full Scale
    TDS Accuracy: 2% Full Scale
    Temp Accuracy: ±0.5°C / ±1°F
    EC Typical EMC Deviation: 2% Full Scale
    TDS Typical EMC Deviation: 2% Full Scale Temp
    Typical EMC Deviation Temperature: ±0.5°C / ±1°F
    Calibration: Automatic, 1 point
    Temperature Compensation: Automatic, with β=0.0 to 2.4%/°C
    Probe: Mi59P (replaceable)
    Environment: 0 to 50°C / 32 to 122°F; max RH 100%
    Battery Type: 4 x 1.5V; IEC LR44, A76 (included)
    Battery Life: Approx. 100 hours of use
    Auto-off: After 8 minutes of non-use
    Dimensions: 7.9 √ó dia 1.5 inches
    Weight: 3.5 ounces

    Returns & Delivery

    How fast will my order ship?

    We're a small family-owned shop, not Amazon. Most orders arrive within 7–14 days, and some items ship direct from the manufacturer. Need it today? Pick it up at Webster or Milford.

    Can I pick this up in store?

    Yes — order online and collect at Webster or Milford with no shipping charge. Both stores are open seven days a week.

    What if I need to return it?

    Most new, unopened items can come back within 30 days of delivery for a full refund. If the mistake was ours, we cover the return shipping.

    Do you handle bulk and commercial orders?

    We ship pallets of Pro-Mix, Bio365 and Athena nationwide. Call 508-461-5850 or ask us for facility pricing.