Description
The TrolMaster Carbon-X CDA-1 is the main controller for a CO2 alarm system. It monitors CO2 in up to 13 zones, with high-level alerts adjustable up to 30,000 ppm and low-level alerts at 5,000 ppm, both adjustable to match local rules for supplemental CO2. When levels climb it can run exhaust fans and dampers, shut the main CO2 valve and signal your facility's fire/alarm panel, and it sends high-CO2 notifications through the TrolMaster app.
- CO2 monitoring for up to 13 zones or rooms (13 sensors per alarm channel)
- Up to 40 controlled outputs for ventilation fans, dampers and main CO2 valves
- Automatic CO2 shut-off with the facility's main CO2 solenoid wired through a control module
- Can signal the fire department through the facility's fire/alarm panel
- Remote monitoring and high-CO2 alerts in the TrolMaster app
- Backlit 128 x 128 LCD with button control; micro-SD for saving and copying settings
- CO2 sensors and audio-visual alarm stations sold separately; TrolMaster calls for an alarm station in each monitored room
- Input: 100–240 VAC, 50/60 Hz · not compatible with HughesNet or Viasat satellite internet
In the box: CDA-1 controller, two 16 ft RJ12 cables, 12 V power adapter.