{"product_id":"milwaukee-mw102-pro-2-in-1-ph-and-temperature-meter-with-atc","title":"Milwaukee MW102 PRO+ 2-in-1 pH and Temperature Meter with ATC","description":"\u003cp\u003e \u003cstrong\u003eSummary\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe digital Milwaukee PRO+ pH Meter is preferred by people testing samples that cause other pH testers and meters to fail from \u003cstrong\u003ebrewers,\u003c\/strong\u003e \u003cstrong\u003ewine makers\u003c\/strong\u003e to hydroponic growers and farmers.\u003c\/p\u003e\n\u003cp\u003eWhen combined and used with the Wine Electrode \u003ca href=\"https:\/\/milwaukeeinstruments.com\/milwaukee-ma919b-1-refillable-combination-ph-probe-for-the-mi456-mini-titrator-and-other-wine-applications\/\"\u003e\u003cu\u003e\u003cstrong\u003eMA919B\/1\u003c\/strong\u003e\u003c\/u\u003e\u003c\/a\u003e, it is a cost effective, reliable portable meter for pH wine applications.\u003c\/p\u003e\n\u003cp\u003eThe Milwaukee PRO pH meter offers:\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003ePeople choose the digital PRO+ pH Meter to improve the accuracy of their pH testing program. With two point calibration, the meter can be quickly calibrated to a higher accuracy compared with one point calibration. The MW102 meter is accuracy to ±0.02 pH. 5x more accurate than some alternative meters.\u003c\/p\u003e\n\u003cp\u003eThe meter comes with both a pH probe and temperature probe allowing the meter to automatically adjust the pH reading for the effect of temperature.\u003c\/p\u003e\n\u003cp\u003eThe temperature probe can also be used as a very accurate thermometer.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eToughness\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe rugged, digital pH meter is built to take knocks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLow Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe PRO+ pH meter comes with the Milwaukee \u003ca href=\"https:\/\/milwaukeeinstruments.com\/milwaukee-se220-lab-grade-double-junction-ph-probe\/\"\u003e\u003cu\u003e\u003cstrong\u003eSE220\u003c\/strong\u003e\u003c\/u\u003e\u003c\/a\u003e pH probe. The \u003ca href=\"https:\/\/milwaukeeinstruments.com\/milwaukee-se220-lab-grade-double-junction-ph-probe\/\"\u003e\u003cu\u003e\u003cstrong\u003eSE220\u003c\/strong\u003e\u003c\/u\u003e\u003c\/a\u003e is Milwaukee's top selling lab grade electrode for a reason. Designed to be both low maintenance (gel filled) and able to withstand more challenging samples (double junction). The \u003ca href=\"https:\/\/milwaukeeinstruments.com\/milwaukee-se220-lab-grade-double-junction-ph-probe\/\"\u003e\u003cu\u003e\u003cstrong\u003eSE220\u003c\/strong\u003e\u003c\/u\u003e\u003c\/a\u003e is ideal for use in beer making, winemaking and hydroponics. \u003c\/p\u003e\n\u003cp\u003eThe PRO MW102 when combined and used with the pH Wine Electrode \u003ca href=\"https:\/\/milwaukeeinstruments.com\/milwaukee-ma919b-1-refillable-combination-ph-probe-for-the-mi456-mini-titrator-and-other-wine-applications\/\"\u003e\u003cu\u003e\u003cstrong\u003eMA919B\/1\u003c\/strong\u003e\u003c\/u\u003e\u003c\/a\u003e, is a reliable portable meter for measuring the pH of wines  \u003cstrong\u003eSEE\u003c\/strong\u003e \u003ca href=\"https:\/\/milwaukeeinstruments.com\/milwaukee-mw102-wine-kit-pro-2-in-1-ph-and-temperature-meter-for-wine\/\"\u003e\u003cu\u003e\u003cstrong\u003eMW102 WINE KIT\u003c\/strong\u003e\u003c\/u\u003e\u003c\/a\u003e.  The \u003ca href=\"https:\/\/milwaukeeinstruments.com\/milwaukee-ma919b-1-refillable-combination-ph-probe-for-the-mi456-mini-titrator-and-other-wine-applications\/\"\u003e\u003cu\u003e\u003cstrong\u003eMA919B\/1\u003c\/strong\u003e\u003c\/u\u003e\u003c\/a\u003e has a special PTFE reference that prevents clogging and staining, can also slide up to drain the reference electrolyte for refilling, is refillable with \u003ca href=\"https:\/\/milwaukeeinstruments.com\/Milwaukee-MA9011-Refilling-Electrolyte-Solution-3.5M-KCl-pH\/ORP-electrodes\/\"\u003e\u003cu\u003e\u003cstrong\u003eMA9011\u003c\/strong\u003e\u003c\/u\u003e\u003c\/a\u003e electrolyte and is glass and designed specific high electrolyte flow.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eDesign features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eFast easy to read results with large digital LCD readout\u003c\/li\u003e\n  \u003cli\u003eLightweight and portable\u003c\/li\u003e\n  \u003cli\u003eEasy measurement: just place the probe in the sample, gently stir and wait for the reading to stabilize\u003c\/li\u003e\n  \u003cli\u003eAutomatic Temp. Compensation (ATC)\u003c\/li\u003e\n  \u003cli\u003eAutomatic two-point calibration for increased accuracy\u003c\/li\u003e\n  \u003cli\u003eExtreme accuracy to ±0.02 pH and extended range (-2.00 pH to 16.00 pH) \u003c\/li\u003e\n  \u003cli\u003eLow maintenance, high performance gel-filled, double junction lab grade pH electrode included\u003c\/li\u003e\n  \u003cli\u003eRugged stainless temperature probe\u003c\/li\u003e\n  \u003cli\u003e3’ probe cables for extra flexibility\u003c\/li\u003e\n  \u003cli\u003eAuto shut off and low power demand\u003c\/li\u003e\n  \u003cli\u003eApprox. 300 hours of continuous use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eCare and Use \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003epH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSensing bulb\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eReference junction\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH electrode will no longer function.\u003c\/p\u003e\n\u003cp\u003eYou can extend the life of your pH electrode in the following ways.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCleaning and Storage\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAll pH sensors have a limited life and response time gets longer with age. Properly maintaining your pH pen tester will give you fast, accurate results for longer. So, be sure to order the Milwaukee pH Maintenance Kit code \u003ca href=\"https:\/\/milwaukeeinstruments.com\/milwaukee-ph-main-maintenance-kit-for-ph-\/-orp-meters-and-testers\/\"\u003e\u003cu\u003e\u003cstrong\u003ePH-Main\u003c\/strong\u003e\u003c\/u\u003e \u003c\/a\u003eat checkout time!  This will be needed to help clean and condition the pH electrode before use!\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.\u003c\/p\u003e\n\u003cp\u003eStore the pH probe in storage solution MA9015.  Only use tap water short-term if \u003ca href=\"https:\/\/milwaukeeinstruments.com\/milwaukee-MW102-pro-ph-meter-with-temperature-probe\/%25%25GLOBAL_ShopPathSSL%25%25\/milwaukee-ma9015-storage-solution-for-ph-\/-orp-electrodes\/\"\u003e\u003cu\u003e\u003cstrong\u003eMA9015\u003c\/strong\u003e\u003c\/u\u003e\u003c\/a\u003e is not immediately available and \u003cstrong\u003eNEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe best way to store the probe is with the probe's cap filled with storage solution or calibration buffer and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCleaning\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eResidue from the sample can impact the sensitivity of the sensing bulb and clog the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution \u003ca href=\"https:\/\/milwaukeeinstruments.com\/milwaukee-ma9016-cleaning-solution-for-ph-\/-orp-electrodes\/\"\u003e\u003cu\u003e\u003cstrong\u003eMA9016\u003c\/strong\u003e\u003c\/u\u003e\u003c\/a\u003e  \u003cstrong\u003efor about 20 minutes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe pH sensing bulbs become less sensitive over time so make sure that you are calibrating regularly to keep your PRO Plus pH meter accurate. Also, calibrate after cleaning or a long period of storage.\u003c\/p\u003e\n\u003cp\u003eThank you for considering Milwaukee to help you take your results to the next level.\u003c\/p\u003e","brand":"Milwaukee","offers":[{"title":"Default Title","offer_id":58456183898415,"sku":"114161","price":188.25,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/4875\/4479\/files\/123e7282MW102__84826_20_281_29.jpg?v=1789194668","url":"https:\/\/mattshydroponics.com\/products\/milwaukee-mw102-pro-2-in-1-ph-and-temperature-meter-with-atc","provider":"Matt’s Hydroponics","version":"1.0","type":"link"}