{"product_id":"milwaukee-mc110-pro-ph-monitor-mid-range","title":"Milwaukee MC110 PRO pH Monitor Mid Range","description":"\u003cp\u003eThe Milwaukee MC110 PRO Mid Range pH monitor offer lab grade accuracy with an easily viewable continuous check on pH levels with alarms.\u003cbr\u003eDESIGN FEATURES\u003cbr\u003eFast easy to read results with large digital LCD readout.\u003cbr\u003eAccuracy to ¬± 0.2 pH with a full 0 pH to 14 pH range.\u003cbr\u003eSet point range of 3.5 to 7.5 pH with visual alarm activated when reading is higher or lower than set point.\u003cbr\u003eComes with full mounting kit including probe holders.\u003cbr\u003eLab grade probe included with a double junction, gel filled design for low maintenance.¬†\u003cbr\u003eStarter Calibration 1 x 20 mL solution M10007B (7.01 pH).\u003cbr\u003eMILWAUKEE PRO PH PROBE CARE¬†\u003cbr\u003epH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.\u003cbr\u003eSENSING BULB\u003cbr\u003eThe glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.\u003cbr\u003eREFERENCE JUNCTION\u003cbr\u003eThe reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH pen will no longer function.You can extend the life of your pH electrode in the following ways.\u003cbr\u003eSTORAGE\u003cbr\u003eThe pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.Storing in pH probe storage solution or pH calibration buffers will help address both these issues.Do not store in tap water and DI water. This will damage the sensitivity of the probe.This best way to store the probe is with the probe's cap filled with storage solution or calibration buffer and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.\u003cbr\u003eCLEANING\u003cbr\u003eResidue from the sample can impact the sensitivity of the sensing bulb and block the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking the probe in cleaning solution.\u003cbr\u003eCALIBRATION\u003cbr\u003eThe pH sensing bulbs become less sensitive over time so make sure that you are calibrating reguarly to keep your PRO pH meter accurate. Also, calibrate after cleaning or a long period of storage.\u003c\/p\u003e\u003cp\u003eSPECIFICATION\u003cbr\u003epH Range: 0.0 - 14.0 pH\u003cbr\u003epH Resolution: 0.1 pH\u003cbr\u003epH Accuracy: ¬± 0.2 pH\u003cbr\u003eCalibration: Manual 2 points\u003cbr\u003eSetpoint range: 3.5 to 7.5 pH\u003cbr\u003eAlarm Active: when reading is higher or lower than set point\u003cbr\u003epH Electrode: MA911B\/2 (included)\u003c\/p\u003e","brand":"Milwaukee Instruments","offers":[{"title":"Default Title","offer_id":58455880499503,"sku":"107644","price":134.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/4875\/4479\/files\/56a68b7a107644.jpg?v=1789191984","url":"https:\/\/mattshydroponics.com\/products\/milwaukee-mc110-pro-ph-monitor-mid-range","provider":"Matt’s Hydroponics","version":"1.0","type":"link"}